LX20 Infrared Sensor

Instruction

Welcome to using LX20 infrared automatic switch!

The product is the new energy-saving switch adopted integrated circuit and the good sensitivity detector. It incorporates automatic, convenient, energy-saving, safe and practical. It works by human motion infrared rays. It can start the controlled load at once when body enters detection field. It can identify day and night automatically. Its installation is very convenient and using range is wide. It has power and detection indication.

SPECIFICATIONS:

Powersource:100V/AC~130V/AC 220V/AC~240V/AC 110V/AC~240V/AC

  Power frequency: 50~60Hz

  Light-control: <10LUX

  Time-delay: Min 5sec Max 6min±1min

  Rated load: 800W (110V/AC) 1200W(220V/AC)

  Detection distance: 6m max (24)

  Detection range: 120°(side view) 360°(top view)

  Working temperature: -20~+40

  Working humidity: <93%RH

  Installation height: 2m ~4m

  Power consumption: 0.5W (static 0.1W)

  Detection speed: 0.6 ~1.5m/s

FUNCTION:

Correct the moving orientation------------Incorrect the moving orientation

INSTALLATION: (see the following figure)

CONNECTION-WIRE DIAGRAM

(see the right figure)

TEST:

NOTES

SOME PROBLEM AND SOLVED WAY

a. Check the power and the load

b. If the load is good

c. If the indicator lamp is green;

d. Please check if the working light correspond to the ambient light

a. Please check if the front of the detection window has the hinder that effect to receive the signals

b. Please check the ambient temperature;

c. Please check if the signals source is in the detection fields;

d. Please check the installation height;

e. If the moving orientation is correct.

a. If it has the continual signals in the detection fields;

b. If the time delay is longest;

c. If the power correspond to the instruction.

d. If the air temperature change near the sensor, for example air condition or central heating etc.