The product is the new energy-saving switch adopted integrated circuit and the good sensitivity detector (LX19BC adopted SMT). It incorporate automatic, convenient, safe, energy-saving and practical function. The wide detection range is made up of the up and down, left and right service field. It works by receiving human motion infrared rays. It can start the controlled load at once when human enter detection field. It can identify automatically day and night. Its using range is wide. It have the functions of the power and the detection indication.

SPECIFICATIONS:

  Power source: 100V/AC~130V/AC 220V/AC~240V/AC

  Power frequency: 50~60Hz

  Ambient light: <10LUX~2000LUX(adjustable)

  Time-Delay : min:8sec±3sec Max:7min±2min

  Detection range: 120°

  Detection distance:9m max (<24°)

  Rated Load: A&B: 400W(110V/AC~130V/AC) 600W(220V/AC~240V/AC)

C: 100W(110V/AX~130V/AC) 200W(220V/AC~240V/AC

  Working temperature:-20~40

  Working humidity: <93%RH

  Installation height: 1m~1.6m

  Power consumption: 0.45W(static 0.1W)

FUNTIONS:

Correct the moving orientation---------------Incorrect the moving orientation

INSTALLATION: (see the following diagram)

CONNECTION-WIRE DIAGRAM LX19A&B

(see the right Fig)

TEST:

 

NOTES:

SOME PROBLEM AND SOLVED WAY :

The load dont work:

a. check the power and the load.

b. If the function switch is in the auto condition.

c. If the load is good.

d. Please check if the working light correspond to the ambient- light.

The sensitivity is poor:

a. Please check if the front of the detection window has the hinder that effect to receive the signals.

b. Please check the ambient temperature.

c. Please check if the signal source is in the detection field.

d. Please check the installation height.

e. If the moving orientation is correct.

The sensor cant shut off the load automatically:

a. If there is the continual sensor signals in the detection field.

b. If the time-delay set the longest.

c. If the power correspond to the instruction.

d. If the temperature change near the sensor. (air condition, central heating etc.)